Product Details:
|
Highlight: | RF Excited CO2 Laser,CO2 Laser,Lasers |
---|
We are a reliable company for expert advice and good service in the field of CO2 laser beam source. Superior beam quality, favourable price, long product lifetime, efficient technical support are the main strengths of our products and service.
CO2 fractional laser scare removal skin resurfacing device
CO2 laser therapy
RF stretch marks removal CO2 fractional laser machine
RF tube laser generator vaginal tightening laser
Cosmetology surgery apparatus
Achieve high speed static or dynamic online marking code
Mark/engrave clearly
Hard-wearing quality
High engraving and marking efficiency
Environmentally-friendly
High and stable power
Cutting better than fiber laser for non-metal
The speed of cutting is faster
Cutting leather, wood, plastics etc
3-5 years long lifetime, stable machine and mode quality
All metal body and very firm
Small size and easy to carry
Quick response time for services
Model | STD-xxx-30A/W | STD-xxx-55A/W |
Wavelength | 9.3 / 10.2 / 10.6μm | 9.3 / 10.6μm |
CW Output Power | ≥30W | ≥55W |
Power Stability | <±5% | <±5% |
Mode | >98%TEM00 | >98%TEM00 |
Beam Size | 1.8±0.2㎜ | 1.8±0.2㎜ |
Beam Divergence | 7.5±0.5 mrad | 7.5±0.5 mrad |
Mode Quality | M²<1.2 | M²<1.2 |
Polarization | >100:1 linear | >100:1 linear |
Weight of Laser System | 5.2kg | 10kg |
Dimension | 357×92.5×142mm | 492.5x92.5x154.5mm |
Input voltage | 48 VDC <±2% | 48 VDC <±2% |
Input DC current | ≤12A | ≤20A |
Ambient Air Temperature | 5℃ to 40℃ | 5℃ to 40℃ |
Cooling | Air or water | Air or water |
Humidity | Non-condensing | Non-condensing |
Laser power is tested at the room temperature 25degree. When the temperature rises 1℃, the output power will reduce 1%.
Definition of stabilization: ±(Pmax-Pmin)/(2Pmax)
Testing condition of stabilization: warming up about 10mins, controlling duty cycle constantly, under the normal operating environment.
STD-xxx-yyz, where xxx means laser wavelength in um (9.3 or 10.6), yy means laser power in watt, and z means cooling in A for air cooling or W for water cooling.
PIN NO | SIGNAL DESCRIPTION |
1 (PWM Orange and white) | RF Enable TTL logic input 1=RF ON,0=RF OFF;1KΩ impedance. This input turns on the laser. (See also Pin 7, Control Enable, below) |
2 (+15V Orange) | +15 VDC±0.5VDC,0.25 A Max output for customer use |
3 (Laser Green and white) | Laser ok TTL logic output,1=LASER OK,0=LASER Fault; Output is asserted when no faults (SWR, Temp or Volt.)are detected |
4 (Temp Blue) | Temperature OK TTL logical output,1=Temp ok,0=Temp fault; Output is asserted when temperature is below 60℃ |
5 (Volt Blue and white) | Power and voltage OK TTL logical output;1= voltage ok,0=voltage fault; Output is asserted when DC supply voltage is below max. value |
6 (GND Green) | For internal use. must be grounded |
7 (Enable Brown and white) | Control enables TTL Logical input;1= Laser control enable,0= Laser controlled disabled This input must be asserted before RF enable can be used to turn on the laser. |
8 (GND Brown) | GND |
Contact Person: Steven
Tel: +86 15671598018
Fax: 86-027-51858989